HXGN15A-12 (F.R) Fixed indoor AC metal enclosed ring network switchgear
HXGN15A-12 (F.R) box type fixed AC metal enclosed ring network switchgear (referred to as "ring network cabinet" for short) is a new type of high-voltage switchgear produced for the reconstruction and construction of urban power grids.
Keyword:
Classify:
Product introduction
◆ Product overview
HXGN15A-12 (F.R) box type fixed AC metal enclosed ring network switchgear (referred to as "ring network cabinet" for short) is a new type of high-voltage switchgear produced for the reconstruction and construction of urban power grids. It is also used for breaking load current, short circuit current and closing short circuit current in the power supply system, and is applicable to the power distribution system of AC 3-10KV and 50Hz. It is widely used in urban power grid construction and transformation projects, industrial and mining industries, high-rise buildings and public facilities, etc. As the ring network power supply unit and terminal equipment, it plays the role of power distribution, control and protection of electrical equipment, and can also be installed in pre installed substations. This ring main unit is equipped with vacuum load switch and spring operating mechanism, which can be operated manually or electrically. The grounding switch and disconnector are equipped with a manual operating mechanism. This ring network cabinet has strong integrity, small size, no risk of combustion and explosion, and has a reliable "five prevention" function.
This product cabinet complies with the relevant provisions of GB3906 3.6-40.5KV AC Metal Enclosed Switchgear and Control Equipment and GBI6926 AC High Voltage Load Switch Fuse Combiner.
◆ Environmental conditions for normal use
1. Ambient air temperature: 15 ℃~+40 ℃;
2. Altitude: 1000m and below;
3. Humidity conditions: daily average relative humidity: ≤ 95%, and daily average steam pressure does not exceed 2.2Kpa; Monthly average relative humidity: ≤ 90%. The monthly average water vapor pressure shall not exceed 1.8Kpa;
4. Seismic intensity: no more than 8 degrees;
5. Places without obvious pollution such as corrosive or flammable gas;
Note: If the above normal use conditions are exceeded, users can coordinate with our company to solve the problem;
◆ Ordering instructions
1. Main circuit scheme, number or main circuit combination arrangement diagram;
2. Electrical schematic diagram of auxiliary circuit and control circuit voltage;
3. Switchgear layout plan;
4. If non-standard main circuits and line schemes are required, we can entrust the company to design and produce them;
5. Other special use conditions.